Skip to main content
  • Letter to the Editor
  • Open access
  • Published:

Non-invasive monitoring of pH and oxygen using miniaturized electrochemical sensors

The Original Article was published on 04 February 2021

Dear Editor,

We read with great interest a recent published article by Pla et al. [1] in Journal of Translational Medicine. In this study, the authors investigated some variables including partial pressure of oxygen, pH, lactate, bicarbonate, and potassium in different time-points of hypoxia induction (i.e., basal, hypoxia-acidosis, and recovery periods). Therefore, they compared these variables between different time-points of measurement in one sample of 27 New Zealand White male rabbits. Since their comparisons were within-group, they were dependent to each others. However, they stated in abstract and statistical analysis section of the methods that one-way analysis of variance (ANOVA) was used to compare variables between different time-points of measurement. One-way ANOVA is used to compare numerical variables with normal distribution between more than two independent groups [2,3,4,5,6]. Because the comparisons in this study was performed between different time-points of measurements in one group of animals, the authors must assess normal distribution of numerical variables and then use repeated measures ANOVA or Friedman test [7,8,9,10]. Furthermore, they used student’s t-test for comparison of numerical variables between each two time-points of measurement, while they must use paired t-test or Wilcoxon for comparison of numerical variables between two time-points of measurement.

Availability of data and materials

Not applicable.

References

  1. Pla L, Berdún S, Mir M, Rivas L, Miserere S, Dulay S, Samitier J, Eixarch E, Illa M, Gratacós E. Non-invasive monitoring of pH and oxygen using miniaturized electrochemical sensors in an animal model of acute hypoxia. J Transl Med. 2021;19:1–11.

    Article  Google Scholar 

  2. Farrokhi M. Reply to: statistical support for Sema3A and multiple sclerosis. Gene. 2017;631:52.

    Article  CAS  Google Scholar 

  3. Farrokhi M, Peykanpour F. Statistical comments on “salivary iron (Fe) ion levels, serum markers of anemia and caries activity in pregnant women.” Rev Bras Ginecol Obstet. 2017;39:583.

    Article  Google Scholar 

  4. Farrokhi M, Masoudifar A, Peykanpour F. Interleukin 17 and 10 in relapsing remitting multiple sclerosis. J Neurol Sci. 2017;378:63.

    Article  CAS  Google Scholar 

  5. Farrokhi M, Amani-Beni A. Statistical comments on “assessment of musculoskeletal strength and levels of fatigue during different phases of menstrual cycle in young adults.” J Clin Diagn Res. 2017;11:CL01.

    PubMed  PubMed Central  Google Scholar 

  6. Farrokhi M. Statistical comments on “does player time-in-game affect tackle technique in elite level rugby union?” J Sci Med Sport. 2018;21:872.

    Article  Google Scholar 

  7. Farrokhi M, Ebrahimi M, Peykanpour F. Effect of surgical intraocular pressure lowering on retinal structures—nerve fibre layer, foveal avascular zone, peripapillary and macular vessel density: 1 year results. Eye. 2020;34:1710.

    Article  Google Scholar 

  8. Farrokhi M. Seasonal variation of vitamin D and Epstein-Barr virus antibody in multiple sclerosis patients. Eur J Neurol. 2018;25:e103.

    Article  CAS  Google Scholar 

  9. Farrokhi M, Nourian NA. Intestinal transplantation and quality of life. Clin Nutr. 2021;40:658.

    Article  Google Scholar 

  10. Farrokhi M, Arjaki D, Peykanpour F. Circulating periostin levels increase in association with bone density loss and healing progression during the early phase of hip fracture in Chinese older women. Osteoporos Int. 2020;31:2061.

    Article  CAS  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

None.

Author information

Authors and Affiliations

Authors

Contributions

MF: study design, writing draft of the study. SPM: study design, writing draft of the study. FT: study design, writing draft of the study. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Mehrdad Farrokhi.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Farrokhi, M., Manavi, S.P. & Taheri, F. Non-invasive monitoring of pH and oxygen using miniaturized electrochemical sensors. J Transl Med 19, 252 (2021). https://doi.org/10.1186/s12967-021-02923-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12967-021-02923-1