Table 1 Comparison of clinical and simulated hemodynamic data before (two left columns) and the first day after initiation of VA-ECMO (two right columns)

From: Individualized real-time clinical decision support to monitor cardiac loading during venoarterial ECMO

 

Before ECMO

+ECMO only

On ECMO first day

Patient

Simulation

Simulation

Patient

Simulation

Heart rate

/min

137

137

137

133

133

Mean arterial pressure

mmHg

85

85

106

98

98

Right ventricular systolic pressure

mmHg

49

49

46

NA

47

Central venous pressure

mmHg

10

10

9

8

9

Left Ventricular end‐diastolic volume

mL

84.6

84.7

93.3

101.1

93.7

Left ventricular end‐diastolic pressure

mmHg

NA

19

23

NA

23

Ejection fraction

%

27.6

27.8

19.5

30.9

23.4

Tricuspid regurgitation velocity

cm/s

311

315

310

NA

NA

ECMO flow

L/min

0

0

2.1

2.1

2.1

  1. The middle column +ECMO only shows effects of solely increasing peripheral ECMO flow from 0 to 2.1 L/min. Simulated data concerning the first day on VA ECMO are adjusted according to clinical data (HR identical, SVR and PVR decreased proportionally to achieve identical MAP, TR removed). Simulation supports the experimental findings of increased LV loading with VA-ECMO. The larger LV and EF in the patient on the first day of VA ECMO is compatible with fluid loading and partial recovery of LV function in addition to the effects of VA-ECMO as supported by clinical data
  2. HR heart rate, SVR systemic vascular resistance, PVR pulmonary vascular resistance, MAP mean arterial pressure, TR tricuspid regurgitation, LV left ventricle and EF ejection fraction, NA data are not available