Skip to main content

Table 2 MC system vs. Harvest centrifugation system; comparison 2

From: Isolation of clinically relevant concentrations of bone marrow mesenchymal stem cells without centrifugation

 

Marrow cellution

Harvest system

TNCs/mL

× 106

CD34+/mL

× 103

CD117+/mL

× 103

TNCs/mL

× 106

CD34+/mL

× 103

CD117+/mL

× 103

Patient 1

23.1

235

348

15.7

91.2

89.7

Patient 2

15.3

135

84.4

28.3

164

76.5

Patient 3

16.4

177

193

44.8

125

89.6

Patient 4

44.1

423

450

55.8

447

463

Patient 5

22.1

315

282

53.7

258

183

Average

24.2 ± 11.6*

257 ± 115

272 ± 141

39.7 ± 17.2

217 ± 143

180 ± 164

  1. Levels of TNCs, CD34+, and CD117+ cells in MC aspirates and Harvest bone marrow concentrates taken from contralateral iliac crest draws in the same patient. (* p < 0.05)