Table 1 Hemodynamic status details of the two groups

From: Effects of intra-aortic balloon pump on cerebral blood flow during peripheral venoarterial extracorporeal membrane oxygenation support

   N group P group
heart rate IABP 92.8 ± 9.6 100.0 ± 13.5
turned off IABP 95.0 ± 13.5 97.8 ± 12.3
systolic pressure (mmHg) IABP 90.8 ± 5.2 89.6 ± 5.4
turned off IABP 89.6 ± 4,9 90.1 ± 4.8
diastolic pressure (mmHg) IABP 79.1 ± 6.2 72.6 ± 5.7
turned off IABP 77.6 ± 5.3 72.6 ± 6.8
mean artery pressure (mmHg) IABP 82.6 ± 5.4 78.9 ± 5.4
turned off IABP 81.6 ± 4.6 77.8 ± 5.7
oxygen saturation (%) IABP 95.0 ± 2.6 94.7 ± 2.4
turned off IABP 94.5 ± 2.4 94.4 ± 2.9
VA ECMO flow (L/min)   3.6 ± 0.2 3.4 ± 0.4
Hct (%)   29.4 ± 4.6 29.7 ± 4.3
  1. No statistically significant hemodynamic changes occurred between the two groups (p > 0.05).